TEKBOX TBCDNE-M3 Coupling Decoupling Networks Emission – 16A, 30 MHz – 300 MHz

$38.31 $58.61
Description TEKBOX TBCDNE-M3 Coupling Decoupling Networks Emission CDNEs are a type of Coupling Decoupling Networks used for an alternative technique of measuring radiated emission of lighting equipment in accordance with the CISPR 15 (EN55015) standard. It avoids the need for emission measurements on Open Area Test Sites. This method was established in CISPR 15 edition 9 as an acceptable alternative to a traditional OATS test configuration that required antennas and calibrated test sites. It is specified for the frequency range from 30 MHz to 300 MHz. The CDNE method and the associated limits up to 300 MHz can only be applied for EUTs with clock frequencies below or equal to 30 MHz. In such a case, the product is deemed to comply with the requirements between 300 MHz and 1000 MHz. When compared to CDNs, CDNEs are substantially more stringently specified, with reduced common mode (CM) impedance tolerance and additional parameters for CM phase tolerance and differential mode impedance equal to 100 Ω. A minimum 20 dB for longitudinal conversion loss shall prevent symmetrical voltage influencing measurement results. CISPR 15 edition 9 also specifies that the mains supply cable of the EUT should be terminated with a CDNE positioned on the reference-ground plane for the OATS, SAC or FAR measurement method. Unlike CDNs, CDNEs are not appropriate for immunity measurements The Tekbox TBCDNE-M3 is designed for measuring EUTs with PE, Neutral, and Line connections. Tekbox offers the TBCDNE-M2 model for measuring EUTs that do not have a PE (Earth) connection. Product Images Setup for emission measurement of an EUT with two cables Learn more... Setup for emission measurement of an EUT with one cable Learn more... Product Videos Conducted Immunity Pre-compliance Test - A CDN method
Cdns – Coupling Decoupling Networks

Cdns – Coupling Decoupling Networks

  • TEKBOX TBCDN-M2 COUPLING DECOUPLING NETWORK – Two lines, 36 Amp, 150 kHz to 230 MHz
    $59.12 $88.68
  • TEKBOX TBCDN-M4 COUPLING DECOUPLING NETWORK – Four lines, 36 Amp, 150 kHz to 230 MHz
    $43.96 $86.16
  • TEKBOX TBCDN-M5 COUPLING DECOUPLING NETWORK – Five lines, 36 Amp, 150 kHz to 230 MHz
    $53.3 $75.15
  • TEKBOX TBCDN-M1 COUPLING DECOUPLING NETWORK – Single Line, 15 Amp, 150 kHz to 230 MHz
    $64.66 $117.68
  • TEKBOX TBCDN-M3 COUPLING DECOUPLING NETWORK – Three lines, 36 Amp, 150 kHz to 230 MHz
    $50.21 $66.28
  • TEKBOX TBCDN-50-150 50 ohm to 150 ohm N-male to N-female adapter
    $63 $108.99
  • TEKBOX TBCDNE-M3 Coupling Decoupling Networks Emission – 16A, 30 MHz – 300 MHz
    $38.31 $58.61

© 2026 - EMS-BAUSTOFFE.DE